APC SMV½Ã¸®Áî
APC SRV½Ã¸®Áî
BACK-UPS½Ã¸®Áî
SMART UPS C ½Ã¸®Áî
SMART UPS ½Ã¸®Áî
SMART UPS SRT½Ã¸®Áî
APC PDU
Easy UPS 3»ó/1»ó
Easy UPS 3»ó/3»ó
APC ATS Àü¿øÀÌÁßÈ­
APC RBCÁ¤Ç°¹èÅ͸®
APC ȣȯ¿ë ¹èÅ͸®±³Ã¼
APC ¼­Áöº¸È£±â ¸ÖƼÅÇ
APC ÀÔ/Ãâ·Â ÄÉÀ̺í
UPS [110VÀü¿ëÁ¦Ç°]
EATON(ÀÌÆ°)UPS
ÇÁ¶û½º¸£±×¶û UPS
PCM-UPS
K-STAR UPS
¿£ÀÌƼUPS
AVR [19"·¢ÀåÂøÇü]
AVR [´Ü»ó/´Ü»ó]
AVR [ȕȗ/ȕȗ]
ÁÖÆļöº¯È¯±â
Àü¾ÐÁÖÆļöº¯È¯±â
ÁÖÆļöº¯È¯±âÀÓ´ë(·»Å»)
Ä«µå°áÀç(°³º°°áÀç)
ÀÚ·á½Ç
Áú¹®°ú ´ë´ä
Áß°í¸Å¸Å
 ÀüÈ­:032-623-0401-2

 Æѽº:032-623-0403

ubkpower@naver.com
ÀºÇà¸í: ±â¾÷ÀºÇà
296-079566-04-014
¿¹±ÝÁÖ:
(ÁÖ)À¯ºñÄÉÀÌ
 
 
ºñ¹Ð¹øÈ£ È®ÀÎ ´Ý±â
EATON(ÀÌÆ°)UPS EATON(ÀÌÆ°)UPS > Eaton9SX½Ã¸®Áî > Eaton 9SX5KIRT/
5KVA[4500W]
 
 
Eaton 9SX5KIRT/
5KVA[4500W]
Á¦Á¶È¸»ç : EATON
ÆǸŰ¡°Ý : °ßÀû¹®ÀÇ
¼ö·® EA
 
 
 
 
 
 

 







 

Eaton 9SX5K iRT3U/5KVA[4500W]
 
General
ÅäÆ÷·ÎÁö On-line double conversion with PFC (Power Factor Correction) system
±¸¼º Rack/Tower
ÆÄÆ® ¹øÈ£ 9SX5KiRT
¿ë·® 5000/4500
Å©±â H x W x D mm 440 x 130 x 685
Áß·®(Kg) 48
º¸Áõ 3 years on electronics, 2 years on battery
 
Electrical Input
¿¬°á
Hardwired - see manual for terminal block layout
Hardwired - example layout only
Input Voltage Range 176-276V without derating (up to 100–276V with derating)
°øĪ Àü¾Ð 200/208/220/230/240V
Frequency 50/60 Hz autoselection
Frequency Range 40-70 Hz
¼ô ½áÅ°Æ® Àü·ù 90 A
THDI <5%
 
Electrical Output
Àü¾Ð 200/208/220/230/240V +/– 1%
Àü¾ÐTHD < 2%
Ãâ·Â Äܼ¾Æ®
(8) IEC-320-C13
C13
(2) IEC-320-C19
C19
Hardwired - see manual for terminal block layout
Hardwired - example layout only
°úºÎÇÏ ³»·® 102–110% : 120s, 110–125%: 60s, 125–150%: 10s, >150%: 500ms
È¿À²(Á¤»ó ¸ðµå) Up to 94% in Online mode, 98% in Hi-Efficiency mode
Ãâ·Â ÁÖÆļö 50/60 Hz autoselect, frequency converter as standard
ºÎÇÏ crest À² 3:1


¹èÅ͸® °ü¸® ABM¢ç and Temperature compensated charging method (user selectable), automatic battery test, deep discharge protection, automatic recognition of external battery units.
ÃàÀüÁö ½ÃÇè EBM (3U)
Deep Discharge Protection Multilingual graphical LCD display
 
Communications
°¡Ã» °æº¸ 1 USB port, 1 RS232 serial port (USB and RS232 ports cannot be used simultaneously), 4 dry contacts (DB9), 1 mini terminal block for remote On/Off and 1 for remote power Off, 1 DB15 for parallel operation.
Relay Output 1 slot for Network-MS card, ModBus-MS or Relay-MS cards
 
Environmental & Standards
¿­ ¹ß»ê(BTU) <45dB
°¡Ã» ¼ÒÀ½ 0 to 40¡ÆC continuous
Standards and Compliance IEC/EN 62040-1, UL 1778, CSA 22.2
Safety markings IEC/EN 62040 -2 , FCC Class A, IEC/EN 62040-3 (Performance)
Ç°Áú CE, CB report (TUV), UL
 
Physical
Bundled With In the interests of continuous product improvement all specifications are subject to change without notice.

 
À̸§ :
³»¿ë :
ÆòÁ¡
 
 
 
ȸ»ç¼Ò°³ ¤Ó ÀÌ¿ë¾È³» ¤Ó ÀÌ¿ë¾à°ü ¤Ó °³ÀÎÁ¤º¸Ã³¸®¹æħ

»óÈ£¸í : (ÁÖ)À¯ºñÄÉÀÌ »ç¾÷ÀÚµî·Ï¹øÈ£ : 130-86-93987 130-86-93987 Åë½ÅÆǸž÷½Å°í¹øÈ£ : Á¦2022-ÀÎõ³²µ¿±¸-0412È£
´ëÇ¥ : Á¶¿Ïâ »ç¾÷Àå¼ÒÀçÁö : ÀÎõ½Ã ³²µ¿±¸ È£±¸Æ÷·Î194 ¸¶Å©¿ø Áö½Ä»ê¾÷¼¾ÅÍ °øÀ嵿5Ãþ529È£(528È£)
ÀüÈ­ : ÀüÈ­:032-623-0401-2,Æѽº:032-623-0403 °³ÀÎÁ¤º¸ º¸È£ Ã¥ÀÓÀÚ : Á¶¿Ïâ
Copyright ¨Ï UBK(ÁÖ)À¯ºñÄÉÀÌ All Rights Reserved.