EATON(ÀÌÆ°)UPS EATON(ÀÌÆ°)UPS > Eaton5PX½Ã¸®Áî > Eaton 5PX3000IRT3U GEN2/
3KVA[2700W]
 
 
Eaton 5PX3000IRT3U GEN2/
3KVA[2700W]
Á¦Á¶È¸»ç : EATON
¼ÒºñÀÚ°¡ : 1,409,000¿ø
ÆǸŰ¡°Ý : °ßÀû¹®ÀÇ
¼ö·® EA
 
 
 
 
 
 

 

Eaton 5PX Gen2 UPS

»õ·Î¿î Eaton 5PX Gen2 UPS´Â ¿£ÅÍÇÁ¶óÀÌÁî ³×Æ®¿öÅ© ¹× Edge IT Àåºñ¿¡ µ¿±Þ ÃÖ°­ÀÇ ¶óÀÎ ÀÎÅÍ·¢Æ¼ºê Àü·Â º¸È£ ±â´ÉÀ» Á¦°øÇÏ¿© IT °ø°£°ú ¼­ºñ½º ¿¬¼Ó¼ºÀ» ±Ø´ëÈ­ÇÕ´Ï´Ù. Eaton 5PX Gen 2´Â ¿ø°Ý ¸ð´ÏÅ͸µ ±â´É°ú  IT ¾ÆÅ°ÅØó¿ÍÀÇ ÅëÇÕ, ´ë±Ô¸ð UPS ¼³Ä¡ ±â¹ÝÀ» ¿ø°ÝÀ¸·Î ±¸Ãà/À¯Áöº¸¼ö µîÀÇ °­·ÂÇÑ ÅøÀ» Á¦°øÇÕ´Ï´Ù.

Eaton 5PX Gen2 UPS

Á¶ÀÛ ÆíÀǼº

Çõ½ÅÀûÀÎ ±×·¡ÇÈ LCD µð½ºÇ÷¹À̸¦ ÅëÇØ 5PX Gen2 ±¸¼ºÀ» ½±°í Á÷°üÀûÀ¸·Î ¼öÇàÇÒ ¼ö ÀÖ½À´Ï´Ù. °£ÆíÇÑ ½ÃÀÛ ±¸¼º ¸¶¹ý»ç¸¦ Á¦°øÇÏ¿© UPS ¼³Á¤ ÇÁ·Î¼¼½º¸¦ ´Ü¼øÈ­ÇÕ´Ï´Ù. Eaton ±â°¡ºñÆ® ³×Æ®¿öÅ© °ü¸® Ä«µå(¿É¼Ç)¸¦ »ç¿ëÇÏ¿© ¿ø°Ý °ü¸® ¹× Æß¿þ¾î ¾÷±×·¹À̵尡 °¡´ÉÇÕ´Ï´Ù. °í±Þ ¹èÅ͸® °ü¸® ¹× ÇÖ ½º¿Ò °¡´ÉÇÑ ¹èÅ͸®¸¦ ÅëÇØ À¯Áö °ü¸®°¡ °£ÆíÇÏ°í À¯¿¬¼ºÀÌ Çâ»óµË´Ï´Ù.

È¿À²¼º

5PX Gen2´Â ÅëÇÕ ÆÄ¿ö ÆÑÅÍ ±â´É ´öºÐ¿¡ ´Ù¸¥ UPSº¸´Ù ¿¬°áµÈ ¼­¹ö¿¡ 11% ´õ ¸¹Àº Àü·ÂÀ» Á¦°øÇÕ´Ï´Ù. Àüü ÀÛµ¿ ¹üÀ§¿¡¼­ ÃÖ´ë È¿À²¼º¿¡ ´ëÇØ Energy Star 2.0 ÀÎÁõÀ» ¹Þ¾Ò½À´Ï´Ù. ¿¡³ÊÁö´Â °¢ ¹èÃⱸ ±×·ìº°·Î ÃøÁ¤µÇ¸ç µð½ºÇ÷¹ÀÌ¿Í EatonÀÇ Intelligent Power Manager¸¦ ÅëÇØ Á÷Á¢ º¼ ¼ö ÀÖ½À´Ï´Ù.

º¸¾È ¹× º¹¿ø·Â

Çʼö ¼­ºñ½ºÀÇ °¡µ¿ ½Ã°£À» ±Ø´ëÈ­Çϱâ À§ÇØ ¿¬°áµÈ ÀåÄ¡ÀÇ ¿ì¼± ¼øÀ§¸¦ ÁöÁ¤ÇÕ´Ï´Ù. ºÎÇÏ ¼¼±×¸ÕÆ® Á¦¾î·Î Àü·Â ½ºÀ§Äª ¹× Àü¿ø º¹±¸¸¦ ½±°Ô °ü¸®ÇÒ ¼ö ÀÖ½À´Ï´Ù. Eaton 5PX Gen2´Â °í±Þ °¡»óÈ­ ±â´ÉÀ¸·Î ¿£ÅÍÇÁ¶óÀÌÁî ¹× Edge IT ¾ÖÇø®ÄÉÀ̼ǿ¡ ÀûÇÕÇÕ´Ï´Ù. Netpack ¸ðµ¨Àº ÀÌÁß »çÀ̹ö º¸¾È ÀÎÁõ(UL 2900-1 ¹× IEC 62443-4-2)À» ÅëÇØ ÄÜÅÙÃ÷¸¦ ´õ¿í º¸È£ÇÏ°í EatonÀÇ »çÀ̹ö º¸¾È ¸ð´ÏÅ͸µ Ŭ¶ó¿ìµå¿¡ ´ëÇÑ ¿¬°áÀ» Á¦°øÇÕ´Ï´Ù.

EATON 5PX GEN2 ¸ðµ¨ ¹× »ç¾ç

Part no. 

5PX1000IRT2UG2

5PX1500IRT2UG2

5PX2200IRT2UG2

5PX3000IRT2UG2

 

 

 

5PX2200IRT3UG2

5PX3000IRT3UG2

Technology

Line-Interactive High Frequency (Pure Sinewave, Booster + Fader)

Power ratings

1000VA / 1000W

1500VA / 1500W

2200VA / 2200W

3000VA / 3000W

UPS Dimensions (H x W x D) mm

438x448x85.5

438x448x85.5

438x603x85.5 (RT2U)  438x483x129 (RT3U)

438x603x85.5 (RT2U) 438x483x129 (RT3U)

UPS Weight

19.6

22.4

28.2 (RT2U) / 27.5 (RT3U)

31.7 (RT2U) / 31.1 (RT3U)

Output connections

8 x IEC C13 (10A)

8 x IEC C13 (10A)

8 x IEC C13 (10A)   2 x IEC C19 (16A)

8 x IEC C13 (10A)2 x IEC C19 (16A)

Input voltage range without using batteries

160V-294V (adjustable to 150V-294V)

Output voltage 

230 V (+6/-10 %) (Adjustable to 200V* / 208V / 220V / 230V / 240V), 50/60 Hz +/- 0.1 Hz (autosensing)

Input frequency range without using batteries

47 to 70 Hz (50 Hz system), 56.5 to 70 Hz (60 Hz system), 40 Hz in low-sensitivity mode

User interface

Graphical LCD display, information on UPS status  and measurements

Warranty

3 years on electronics, 2 years on battery

Standards and certifications

Energy Star 2.0 certified, CB Test Certification, CE Test Certification -safety requirements, Electromagnetic compatibility requirements, Restriction of hazardous substances (RoHS 3)

 
À̸§ :
³»¿ë :
ÆòÁ¡
 
 
 
ȸ»ç¼Ò°³ ¤Ó ÀÌ¿ë¾È³» ¤Ó ÀÌ¿ë¾à°ü ¤Ó °³ÀÎÁ¤º¸Ã³¸®¹æħ

»óÈ£¸í : (ÁÖ)À¯ºñÄÉÀÌ »ç¾÷ÀÚµî·Ï¹øÈ£ : 130-86-93987 [»ç¾÷ÀÚÁ¤º¸È®ÀÎ] Åë½ÅÆǸž÷½Å°í¹øÈ£ : Á¦2022-ÀÎõ³²µ¿±¸-0412È£
´ëÇ¥ : Á¶¿Ïâ »ç¾÷Àå¼ÒÀçÁö : ÀÎõ½Ã ³²µ¿±¸ È£±¸Æ÷·Î194 ¸¶Å©¿ø Áö½Ä»ê¾÷¼¾ÅÍ °øÀ嵿5Ãþ529È£(528È£)
ÀüÈ­ : ÀüÈ­:032-623-0401-2,Æѽº:032-623-0403 °³ÀÎÁ¤º¸ º¸È£ Ã¥ÀÓÀÚ : Á¶¿Ïâ
Copyright ¨Ï UBK(ÁÖ)À¯ºñÄÉÀÌ All Rights Reserved.